Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 1189AP Coax - Broadband CATV Coaxial Cable For more Information please call 1-800-Belden1 General Description: 18 AWG solid .040" bare copper-covered steel conductor, foam FEP insulation, Duobond(R) IV quad shield (60% and 40% coverage), PVC jacket. Physical Characteristics (Overall) Conductor AWG: # Coax AWG Stranding Conductor Material 1 18 Solid Dia. (in.) BCCS - Bare Copper Covered Steel .040 Total Number of Conductors: 1 Insulation Insulation Material: Insulation Material Dia. (in.) FFEP - Foam Fluorinated Ethylene Propylene .170 Outer Shield Outer Shield Material: Layer # Outer Shield Trade Name Type Outer Shield Material 1 Bonded Duofoil(R) 2 3 Coverage (%) Tape Bonded Aluminum Foil-Polyester Tape-Aluminum Foil 100 Duofoil(R) 4 Braid AL - Aluminum 60 Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100 Braid AL - Aluminum 40 Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Flamarrest(R) LS PVC - Low Smoke Polyvinyl Chloride Overall Cable Overall Nominal Diameter: 0.248 in. Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +75C Bulk Cable Weight: 29 lbs/1000 ft. Max. Recommended Pulling Tension: 162 lbs. Min. Bend Radius/Minor Axis: 2.500 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CATVP CEC/C(UL) Specification: CMP EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes Page 1 of 3 12-03-2013 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 1189AP Coax - Broadband CATV Coaxial Cable EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Series Type: Series 6 Flame Test UL Flame Test: UL910 Plenum Plenum/Non-Plenum Plenum (Y/N): Yes Non-Plenum Number: 1189A Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) 75 Nom. Inductance: Inductance (H/ft) .097 Nom. Capacitance Conductor to Shield: Capacitance (pF/ft) 16.3 Nominal Velocity of Propagation: VP (%) 83 Nominal Delay: Delay (ns/ft) 1.220 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/1000 ft) 28.0 Nominal Outer Shield DC Resistance: DCR @ 20C (Ohm/1000 ft) 4.8 Nom. Attenuation: Freq. (MHz) Attenuation (dB/100 ft.) 1 .3 10 .66 50 1.6 100 2.2 200 3.0 400 4.6 700 6.6 900 7.7 1000 8.2 Max. Operating Voltage - UL: Voltage 300 V RMS Minimum Structural Return Loss: Description Freq. (MHz) Start Freq. (MHz) Stop Freq. (MHz) Min. SRL (dB) 5 1000 20 Page 2 of 3 12-03-2013 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 1189AP Coax - Broadband CATV Coaxial Cable Sweep Test Sweep Testing: 5 MHz - 1 GHz Put Ups and Colors: Item # Putup Ship Weight Color Notes Item Desc 1189AP 8771000 1,000 FT 32.000 LB NATURAL C RG-6 PLENUM QUAD SH Notes: C = CRATE REEL PUT-UP. Revision Number: 4 Revision Date: 11-14-2013 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 12-03-2013